Operating SystemWindows Embedded Compact
BSP Release Status

RELEASED

Release Date

  

Repository 
Binariesftp://ftp.phytec.com/products/PFL-A-02_phyFLEX-iMX6/Compact7/PD13.1.0/
Source Archive 
Release Notes

Click Here


Introduction

This BSP provides a basis for development, deployment and execution of Compact 7 based applications on the phyFLEX-i.MX6 System on Module (SOM). For detailed information on the various software components included in the release and how to use them, please refer to the Quickstart.

Versioning

ComponentVersion
Windows Embedded Compact7
 

This Release is compatible with the following hardware:

BSP Release VersionBSP Release DateSOM PCB VersionFLEX Mapper Board VersionFLEX Baseboard Version
PD13.1.0April 5th, 20131362.11367.11364.2

BSP Download

Release PD13.1.0 can be downloaded from the link below.

ftp://ftp.phytec.com/products/PFL-A-02_phyFLEX-iMX6/Compact7/PD13.1.0/

Quickstart

Release PD13.1.0 should be used in conjunction with Quickstart version PD13.1.0:

What’s Supported

This BSP Release supports the following components:

  • i.MX6: Windows Embedded Compact 7
  • NAND Flash: Bootloader (EBOOT); OS image (NK.bin)
  • DDRAM: MT41J128M16HA-15E IT DDR3
  • UART: UART0 (Debug); UART1
  • USB: USB0 HS OTG; USB1 HS Host
  • Ethernet: 10/100/100 Mbit/s – ETH0 from RGMII
  • CAN: CAN0
  • SD/MMC: SD0; SD1
  • SPI driver: SPI0, SPI1 enabled
  • I2C driver: I2C0, I2C1 enabled
  • EEPROM: at24 on I2C1
  • Touch

Resistive: STMPE811 on I2C0 (device on carrier board)

  • Display:

Prime View PM070WL4 LVDS (LCD-017-070W)

  • Graphics: OpenGL/VG

Note: Signal names may change between processor and PCBs. Please refer to phyFLEX-i.MX6 Hardware Manual for signal name mapping.

What’s Not Supported

This BSP Release does not support the following components:

  • RTC: RTC-8564 Real-Time Clock on I2C0 (device on carrier board)
  • PCIe
  • SATA
  • Display

EDT ETM0700G0DH6 TTL (LCD-018-070-KAP)

  • Audio: Line in, Line out, Mixer, Mic in
  • Camera Interface: MT9M001, MT9V022
  • Video decoding
  • Video encoder: Streaming, TV

Fixed in this Release

  • Ethernet now works with a direct connection

New in this Release

  • HDMI
  • CAN
  • SPI

Known Issues

  • Sometimes the system hangs on startup (1 of 100 boots)
  • Checked Build is not working
  • DEBUG Build works only without SD Card Driver

Workaround: Remove SD Card Driver from the Catalog

Upgrade and Compatibility Information

This BSP is not backwards compatible due to a change in PCB pinout, see Modification of the pinout for the phyFLEX-i.MX6 (PLF-A-XL1). The BSP is specific to SOM: 1362.1 and Carrier Board: 1364.2 and will retain compatibility with future released PCB revisions.

Dependencies

N/A

Validation Information

Drivers have been tested with a combination of in-house test cases, as well as with the Windows Embedded Compact7 Test Kit (installed along with Windows Compact 7) where applicable.

Technical Support

For further information or to report any problems, contact PHYTEC Technical Support.