Date: Fri, 29 Mar 2024 16:00:24 +0100 (CET) Message-ID: <1539679082.36.1711724424916@[172.25.0.138]> Subject: Exported From Confluence MIME-Version: 1.0 Content-Type: multipart/related; boundary="----=_Part_35_824549888.1711724424914" ------=_Part_35_824549888.1711724424914 Content-Type: text/html; charset=UTF-8 Content-Transfer-Encoding: quoted-printable Content-Location: file:///C:/exported.html
This BSP provides a basis for development, deployment and execution of C= ompact 7 based applications on the phyCORE-AM335X System on Module (SOM). F= or detailed information on the various software components included in the = release and how to use them, please refer to the 45646227.
This Release is compatible with the following hardware:
BSP Release Version | BSP Release Date | SOM PCB Version | CB PCB Version |
---|---|---|---|
PD13.2.1_EA1 | November 13th, 2013 | 1358.3 | 1359.3 |
1358.2 [1] | 1359.2 |
[1] Due to updated RAM timings different software is required to bo= ot the board. Please use BSP Download 1358.2 images that have a m= odified XLDR version.
Release PD13.2.1_EA1 can be downloaded from the link below.
ftp://ftp.phytec.c= om/products/PCM-051_phyCORE-AM335x/Compact7/PD13.2.1_EA1/
Pay special attention to your SOM board revision. Due to updated RAM tim= ings, XLDR for SOM revision 1358.2 (PCM-051-12102F0I.A0) should be download from the link below:
= ftp://ftp.phytec.com/products/PCM-051_phyCORE-AM335x/Compact7/PD13.2.1_EA1/= Bootloader/1358.2/
Release PD13.2.1_EA1 should be used in conjunction with Quickstart versi= on L-780e_0:
This BSP Release supports the following components:
EEPROM: at24 on I2C_0RTC: RV-4162-C7 external RTC on I2C_0PMIC: TPS65910= A3 on I2C_0TSC: Resistive: STMPE811 on I2C0 (device on carrier board); Capa= citive: FocalTech FT5306 on I2C0
HeadlessEDT ETM0700G0DH6 TTL (LCD-018-070-KAP)Prime View PD050VL1 LVDS (= LCD-017-050V)Prime View PM070WL4 LVDS (LCD-017-070W)Prime View PD104SLF LVD= S (LCD-017-104S)Hitachi TX09D70VM1CCA TFT (LCD-011)
This BSP Release does not support the following components:
Device hangs after disconnect the Ethernet cableIf the device boot up wi= thout connected Ethernet cable it takes 40 seconds more time to boot.
Workaround: Disable the Windows system sounds to get Audio working = on running system.
To upgrade to a new BSP release, use the Windows uninstaller to remove t= he existing BSP via Start->Control Panel->Uninstall a progra= m. Then install the new BSP using the Microsoft installer package or e= xecutable, e.g., <device name>-Compact7_BSP_Source-PDxx.x.x.msi.
N/A
Drivers have been tested with a combination of in-house test cases, as w= ell as with the Windows Embedded Compact7 Test Kit (installed along with Wi= ndows Compact 7) where applicable.
For further information or to report any problems, contact PHYTEC Technical Support.