This BSP provides a basis for development, deployment and execution of Compact 7 based applications on the phyCORE-AM335X System on Module (SOM). For detailed information on the various software components included in the release and how to use them, please refer to the Quickstart.
|
This Release is compatible with the following hardware:
BSP Release Version | BSP Release Date | SOM PCB Version | CB PCB Version |
---|---|---|---|
PD13.2.0 | 7/11/2013 | 1358.3 [1] | 1359.3 |
1358.2 | 1359.2 |
[1] Due to updated RAM timings different software is required to boot the board. Please use BSP Download PCM-051-12102F0C.A1 images that have modified versions of the bootloaders.
Release PD13.2.0 can be downloaded from the link below.
ftp://ftp.phytec.com/products/PCM-051_phyCORE-AM335x/Compact7/PD13.2.0/
Pay special attention to your SOM board revision. Due to updated RAM timings, the bootloaders for SOM revision 1358.3 (PCM-051-12102F0C.A1) should be download from the link below:
Release PD13.2.0 should be used in conjunction with Quickstart version L-780e_0:
This BSP Release supports the following components:
EEPROM: at24 on I2C_0RTC: RV-4162-C7 external RTC on I2C_0PMIC: TPS65910A3 on I2C_0TSC: Resistive: STMPE811 on I2C0 (device on carrier board); Capacitive: FocalTech FT5306 on I2C0
This BSP Release does not support the following components:
Device hangs after disconnect the ethernet cableIf the device boot up without connected ethernet cable it takes 40 seconds more time to boot.
Workaround: Disable the Windows system sounds to get Audio working on running system.
To upgrade to a new BSP release, use the Windows uninstaller to remove the existing BSP via Start->Control Panel->Uninstall a program. Then install the new BSP using the Microsoft installer package or executable, e.g., <device name>-Compact7_BSP_Source-PDxx.x.x.msi.
N/A
Drivers have been tested with a combination of in-house test cases, as well as with the Windows Embedded Compact7 Test Kit (installed along with Windows Compact 7) where applicable.
For further information or to report any problems, contact PHYTEC Technical Support.