Operating SystemWindows CE
BSP Release Status

Release Date
 
Repository 
Binaries

ftp://ftp.phytec.com/products/PCM-051_phyCORE-AM335x/Compact7/PD13.2.1_EA1/

Important:

Pay special attention to your SOM board revision. Due to updated RAM timings, XLDR for SOM revision 1358.2 (PCM-051-12102F0I.A0) should be download from the link below:

ftp://ftp.phytec.com/products/PCM-051_phyCORE-AM335x/Compact7/PD13.2.1_EA1/Bootloader/1358.2/

Source Archive 
Release Notes

Click Here







Introduction

This BSP provides a basis for development, deployment and execution of Compact 7 based applications on the phyCORE-AM335X System on Module (SOM). For detailed information on the various software components included in the release and how to use them, please refer to the 45646227.

Versioning




ComponentVersion
Windows Embedded CompactBased on TI Release BSP_WINCE_A8 2.00.00.01



 


This Release is compatible with the following hardware:

BSP Release VersionBSP Release DateSOM PCB VersionCB PCB Version
PD13.2.1_EA1November 13th, 20131358.31359.3
1358.2 [1]1359.2

[1] Due to updated RAM timings different software is required to boot the board. Please use BSP Download 1358.2 images that have a modified XLDR version.

BSP Download

Release PD13.2.1_EA1 can be downloaded from the link below.

ftp://ftp.phytec.com/products/PCM-051_phyCORE-AM335x/Compact7/PD13.2.1_EA1/

Important:

Pay special attention to your SOM board revision. Due to updated RAM timings, XLDR for SOM revision 1358.2 (PCM-051-12102F0I.A0) should be download from the link below:

ftp://ftp.phytec.com/products/PCM-051_phyCORE-AM335x/Compact7/PD13.2.1_EA1/Bootloader/1358.2/

Quickstart

Release PD13.2.1_EA1 should be used in conjunction with Quickstart version L-780e_0:

What’s Supported

This BSP Release supports the following components:

EEPROM: at24 on I2C_0RTC: RV-4162-C7 external RTC on I2C_0PMIC: TPS65910A3 on I2C_0TSC: Resistive: STMPE811 on I2C0 (device on carrier board); Capacitive: FocalTech FT5306 on I2C0

HeadlessEDT ETM0700G0DH6 TTL (LCD-018-070-KAP)Prime View PD050VL1 LVDS (LCD-017-050V)Prime View PM070WL4 LVDS (LCD-017-070W)Prime View PD104SLF LVDS (LCD-017-104S)Hitachi TX09D70VM1CCA TFT (LCD-011)

What’s Not Supported

This BSP Release does not support the following components:

Fixed in this Release

Device hangs after disconnect the Ethernet cableIf the device boot up without connected Ethernet cable it takes 40 seconds more time to boot.

New in this Release

Known Issues

Workaround: Disable the Windows system sounds to get Audio working on running system.

Upgrade and Compatibility Information

To upgrade to a new BSP release, use the Windows uninstaller to remove the existing BSP via Start->Control Panel->Uninstall a program. Then install the new BSP using the Microsoft installer package or executable, e.g., <device name>-Compact7_BSP_Source-PDxx.x.x.msi.

Dependencies

N/A

Validation Information

Drivers have been tested with a combination of in-house test cases, as well as with the Windows Embedded Compact7 Test Kit (installed along with Windows Compact 7) where applicable.

Technical Support

For further information or to report any problems, contact PHYTEC Technical Support.