This BSP provides a basis for development, deployment and execution of Linux based applications on the phyCORE-OMAP44XX System on Module (SOM). For detailed information on the various software components included in the release and how to use them, please refer to the Quickstart.
|
This Release is compatible with the following hardware:
BSP Release Version | BSP Release Date | SOM PCB Version | CB PCB Version |
---|---|---|---|
PD13.1.0 | August 6th, 2013 | 1347.3 | 1348.2 |
1347.2 [1] | |||
1347.1 [2] |
[1] Does not contain PMIC Errata fix[2] Does not contain PMIC Errata fix; OMAP4430 variant (not fully tested with release)
Release PD13.1.0 can be downloaded from the link below.
ftp://ftp.phytec.com/products/PCM-049_phyCORE-OMAP44xx/Linux/PD13.1.0/
Use the link below for WiFi enabled images.
ftp://ftp.phytec.com/products/PCM-049_phyCORE-OMAP44xx/Linux/PD13.1.0/wifi/
Release PD13.1.0 should be used in conjunction with Quickstart version PD13.1.0:
This BSP Release supports the following components:
Resistive: STMPE811 on I2C_4 @ 0x41 (device on carrier board)Capacitive: FocalTech FT5306
Prime View PM070WL4 LVDS (LCD-017-070W)Prime View PD104SLF LVDS (LCD-017-104S)EDT ETM0700G0DH6 TTL (LCD-018-070-KAP)
This BSP Release does not support the following components:
Refer to the following for additional information: Important thermal shutdown management feature in new BSP release
Workaround: Apply the software patch, 0001-pcm049-wl12xx-use-set_power-to-control-WL_EN.patch, to the Linux source directory before enabling WiFi.
Workaround: See Update the Linux kernel MD5SUM in the Quickstart
Workaround: See Images Building Images in the Quickstart. Use the alternative download link for the files listed below, download the file, place it in phyCORE-OMAP4-PD13.1.0/src directory in its compressed form, and restart the build process by calling ptxdist go again.qt-everywhere-opensource-src-4.8.4.tar.gz --- Download linkorc-0.4.16.tar.gz --- Download Linku-boot-2011.12.tar.bz2 --- Download Link
To upgrade to a new BSP release, simply delete the old release and extract the new release in its place.
N/A
Drivers have been tested with in-house test cases. Primarily tested with OMAP4460.
For further support please visit PHYTEC's Support Portal