This BSP provides a basis for development, deployment and execution of Linux based applications on the phyFLEX-i.MX6 System on Module (SOM). For detailed information on the various software components included in the release and how to use them, please refer to the Quickstart.
|
This Release is compatible with the following hardware:
BSP Release Version | BSP Release Date | SOM PCB Version | FLEX Mapper Board Version | FLEX Baseboard Version |
---|---|---|---|---|
PD13.2.2_EA2 | October 17th, 2013 | 1362.2 | 1367.3 | 1364.4 |
1362.1 | 1367.2 [1] | 1364.3 [1] | ||
1367.1 [2] | 1364.2 [1] |
[1] Does not fully support PCIe. FLEX Mapper board does not include nPCIe0_PERST. FLEX Baseboard missing 100Ω termination resistor on PCIe clock and reset for an extra PCIe.[2] Hardware interface does not support Camera0 interface extension and full 18-bit Camera0 (missing J6 and J7 for CSI0_DAT3 and CSI0_DAT2 signal multiplexing). Different reset out circuitry for Camera0 and Camera1. JP12 does not exist (X_CAMERA1_CLK & X_CAMERA0_CLK).
Release PD13.2.2_EA2 can be downloaded from the link below.
ftp://ftp.phytec.com/products/PFL-A-02_phyFLEX-iMX6/Linux/PD13.2.2_EA2/
Release PD13.2.2_EA2 should be used in conjunction with Quickstart version PD13.2.0:
This BSP Release supports the following components:
Resistive: STMPE811 on I2C0 (device on Baseboard)Capacitive: FocalTech FT5306 on I2C0
Prime View PD050VL1 LVDS (LCD-017-050V)Prime View PM070WL4 LVDS (LCD-017-070W)Prime View PD104SLF LVDS (LCD-017-104S)EDT ETM0700G0DH6 TTL (LCD-018-070-KAP)DVI / HDMI
VM-006-BWVM-009VM-010-BWVM-011-BW (phyCAM-P)VM-011-COL (phyCAM-S)USB-CAM-003H (with UVC Firmware update)USB-CAM-103H (with UVC Firmware update) (without trigger)USB-CAM-051H (with UVC Firmware update)USB-CAM-151H (with UVC Firmware update) (without trigger)
Note: Signal names may change between processor and PCBs. Please refer to phyFLEX-i.MX6 Hardware Manual for signal name mapping.
This BSP Release does not support the following components:
VM-011-BW and VM-011-COL (phyCAM-P and phyCAM-S)new bootargs (configuration possible)individual camera frequenciesExtended gstreamer Examples (mpeg4 decoding by VPU-Hardware and Freescale sink examples for better Bimage presentation[low tearing, low CPU-load])
firmware-imx-3.0.35-4.0.0imx-lib-3.0.35-4.0.0imx-test-3.0.35-4.0.0kobs-ng-3.0.35-4.0.0libfslvpuwrap-1.0.35libfslparser-3.0.7libfslcodec-3.0.7gst-fsl-plugins-3.0.7gpu-fsl-3.0.35-4.0.0gpu-fsl-test-3.0.35-4.0.0camera documentation
This BSP is not backwards compatible and has no workaround for 1362.0 SOM and 1364.1 Baseboard due to a change in PCB pinout, see Modification of the pinout for the phyFLEX-i.MX6 (PLF-A-XL1).
N/A
Drivers have been tested with in-house test cases.
For further support please visit PHYTEC's Support Portal