Operating SystemLinux
BSP Release Status

Release Date

  

Repository 
Binariesftp://ftp.phytec.com/products/PFL-A-02_phyFLEX-iMX6/Linux/PD13.2.2_EA2/
Source Archive 
Release Notes

Click Here


Introduction

This BSP provides a basis for development, deployment and execution of Linux based applications on the phyFLEX-i.MX6 System on Module (SOM). For detailed information on the various software components included in the release and how to use them, please refer to the Quickstart.

Versioning

ComponentVersion
Linux Kernel3.0.35
Barebox2013.08.0
PTX Distribution2012.03.0
OSELAS Toolchain2011.11.1
 

This Release is compatible with the following hardware:

BSP Release VersionBSP Release DateSOM PCB VersionFLEX Mapper Board VersionFLEX Baseboard Version
PD13.2.2_EA2October 17th, 20131362.21367.31364.4
1362.11367.2 [1]1364.3 [1]
1367.1 [2]1364.2 [1]

[1] Does not fully support PCIe. FLEX Mapper board does not include nPCIe0_PERST. FLEX Baseboard missing 100Ω termination resistor on PCIe clock and reset for an extra PCIe.[2] Hardware interface does not support Camera0 interface extension and full 18-bit Camera0 (missing J6 and J7 for CSI0_DAT3 and CSI0_DAT2 signal multiplexing). Different reset out circuitry for Camera0 and Camera1. JP12 does not exist (X_CAMERA1_CLK & X_CAMERA0_CLK).

BSP Download

Release PD13.2.2_EA2 can be downloaded from the link below.

ftp://ftp.phytec.com/products/PFL-A-02_phyFLEX-iMX6/Linux/PD13.2.2_EA2/

Quickstart

Release PD13.2.2_EA2 should be used in conjunction with Quickstart version PD13.2.0:

What’s Supported

This BSP Release supports the following components:

Resistive: STMPE811 on I2C0 (device on Baseboard)Capacitive: FocalTech FT5306 on I2C0

Prime View PD050VL1 LVDS (LCD-017-050V)Prime View PM070WL4 LVDS (LCD-017-070W)Prime View PD104SLF LVDS (LCD-017-104S)EDT ETM0700G0DH6 TTL (LCD-018-070-KAP)DVI / HDMI

VM-006-BWVM-009VM-010-BWVM-011-BW (phyCAM-P)VM-011-COL (phyCAM-S)USB-CAM-003H (with UVC Firmware update)USB-CAM-103H (with UVC Firmware update) (without trigger)USB-CAM-051H (with UVC Firmware update)USB-CAM-151H (with UVC Firmware update) (without trigger)

Note: Signal names may change between processor and PCBs. Please refer to phyFLEX-i.MX6 Hardware Manual for signal name mapping.

What’s Not Supported

This BSP Release does not support the following components:

Fixed in this Release

New in this Release

VM-011-BW and VM-011-COL (phyCAM-P and phyCAM-S)new bootargs (configuration possible)individual camera frequenciesExtended gstreamer Examples (mpeg4 decoding by VPU-Hardware and Freescale sink examples for better Bimage presentation[low tearing, low CPU-load])

firmware-imx-3.0.35-4.0.0imx-lib-3.0.35-4.0.0imx-test-3.0.35-4.0.0kobs-ng-3.0.35-4.0.0libfslvpuwrap-1.0.35libfslparser-3.0.7libfslcodec-3.0.7gst-fsl-plugins-3.0.7gpu-fsl-3.0.35-4.0.0gpu-fsl-test-3.0.35-4.0.0camera documentation

Known Issues

Upgrade and Compatibility Information

This BSP is not backwards compatible and has no workaround for 1362.0 SOM and 1364.1 Baseboard due to a change in PCB pinout, see Modification of the pinout for the phyFLEX-i.MX6 (PLF-A-XL1).

Dependencies

N/A

Validation Information

Drivers have been tested with in-house test cases.

Technical Support

For further support please visit PHYTEC's Support Portal