The following is a guide for how to connect up PHYTEC's 10" LVDS display and resistive touch solution to the phyBOARD-Mira i.MX6. This optional add on includes the following components:
Targeted Hardware | phyCORE-i.MX6, phyBOARD-Mira i.MX6 |
Targeted Software | phyBOARD-Mira i.MX6 PD15.2.0 |
Date | 2/25/2016 |
Step-by-step guide
The BSP has already been configured to support the display but it must be enabled as an expansion in Barebox. To activate the display enter the following in Barebox. See the phyBOARD-Mira i.MX6 Quickstart for more information.
edit /env/config-expansions |
Add the following line.
. /env/expansions/imx6qdl-mira-enable-lvds # Enable for 10" LVDS Display AUO G104SN02-V2 with resistive touch |
On the first boot a touch screen calibration is recommended. To run this the default Qt application must be stopped. After calibration it can be restarted.
systemctl stop qt5demo.service ts_calibrate systemctl start qt5demo.service |
Related articles appear here based on the labels you select. Click to edit the macro and add or change labels.
|